Modular Construction Defined
Frequently asked
questions include:
What is
the difference between structures that are constructed on
site, and those that are constructed modularly, in a
factory?
Some
structures are constructed on site, and are conceivably
moveable, but what differentiates these structures from
those that are modularly constructed in a factory?
These
questions are answered by both investigating the original
building design and an term called inherent permanency.
Inherent permanency is a definition that addresses the
question of "Is this structure designed and intended for
permanent use?" This issue is relevant, as nearly any
structure can be moved. To the extreme end of that scale,
the London Bridge was moved to Arizona - but certainly no
one will say that this represents relocatability. The
question of inherent permanence asks at what point can you
consider a structure easily movable and when is it not
easily relocatable or reasonably achievable.
Utilizing the
six-way test that was established in the Federal court cases
of Whiteco and further used extensively in the Fox Photo
case ( a modular commercial structure), the courts recommend
that it be viewed under the 6 way test as established in the
Whiteco case:
1. Is the
property capable of being moved and has it in fact been
moved?
To facilitate
off-site construction, modular construction requires the
manufacture and transport of sectional units from the
factory to another site where they will be connected
together. The practice of assembly and disassembly of
modular units is an everyday industry occurrence. The
modular units are designed to be legally transported form
the factory over the public highway before use, therefore,
reuse after disassembly is commonplace in practice and
intended. Further, under contractual obligation, typically
the structure must be removed at the termination of the
contract of when needed. This most likely will not be the
case for on-site constructed facilities.
2. Is the
property designed or constructed to remain permanently in
place?
Non-residential modular construction typically is designed
and manufactured to be readily relocatable. Foundation
systems that are used by modular structures are a function
of compliance with locally prescribed model construction
codes to support the structure. Depending on the prevailing
local construction codes, foundation systems, not the
structure, may or may not be sedentary or appear to be
permanent.
For buildings
leased, the term of the average original operating lease
contract is, typically less than five years. At the
termination of the lease, the structure must be removed from
the site, relocated, and then would be utilized at another
site.
Since the
structure's modular units are initially intrinsically
designed to be transported for highway movement from the
factory to the first site, these structural units maintain
their transportability for secondary, and subsequent moves.
For these secondary moves, the act of disassembly typically
does not substantially damage these sectional modular units.
Additionally, it is common that once the modular units are
removed, many of these units may be inventoried,
re-configured, and reused at other sites.
3. Are
there circumstances that show that the property may or will
be moved?
The term of
the lease or the use of the structure dictates the removal
of the modular sections. At the termination of the lease or
use, lessor or user is required to disassemble and transport
each of the modular section to another site or return to
inventory for re-use at a later time.
Since these
structure are initially constructed in a remote factory,
this design allows an industry-wide marketing application of
short use of the structure in one location and the ready
relocation to another site. This practice is prevalent in
the educational, office, airport, institutional, restaurant,
correctional, and medical facilities' markets to name but a
few.
Since these
structures have been transported over public highways at
least once, the ability exists universally to disassemble
and re-transport sectional units with minimal costs for
permits and transit. The fees to obtain local disassembly
permits are nominal in cost as well.
4. How
substantial a job is removal of the property, and how time
consuming?
The job of
removing the modular sections of the structures is
facilitated by the very initial design and manufacture of
the sectional units. Because of the inherent sectional
design, disassembly time is minimal. Typical of costs,
including time consumed and materials for disassembly and
removal, are less the 20% of the replacement costs of the
total structure.
Typical
disassembly time is less than the time spent in the initial
assembly.
Typical
removal includes disassembly and transportation to another
site or to storage. Once in storage, the sectional units may
again be transported and reassembled or reconfigured to suit
the needs of the next lessee or owner. It is common industry
practice to inventory sectional units, and re-configure on a
site, as directed by the lessee of owner.
The question
of cost, time and intrinsic design provide the contrast
between readily relocatable and improbability and costly
relocation of a structure.
5. How
much damage will the property sustain upon removal?
Since these
sectional units are inherently designed, manufactured, and
transported in sectional format for site coupling, these
units suffer minimal damage during disassembly. Typically
disassembly and removal damage is less the 10% percent of
replacement costs to the property. Once disassembled and
transported, each sectional unit is capable of being readily
re-used in another application or site.
Site
restoration costs are minimal after removal, and is usually
addressed in contract language, therefore the intent to
remove the structure is an integral part of the design and
application. Contract leases typically specify that the
structure is personal property in finite land and structure
leases.
6. What is
the manner of affixation to the property to the land?
For the
non-residential modular industry, the manner of affixation
to the property is typically determined by local prevailing
model construction codes. The manner of affixation to the
site is not an indication of intent of permanence, rather it
is a commonplace, as most states have a preemptive
state-wide construction code for the structure, and local
agencies determine appropriate foundation, utility, and land
use issues.
The
affixation between the structure and the foundation system
can be varied. With pier and pad systems, it is gravity or
bolted systems or tack-welded systems. The attachment to the
foundation is determined by structural requirements and not
by intention of permanence.
Typical
foundation systems used in conjunction with modular units
allow for ready return to pre-installation status with
little or minor site reconstruction costs. Foundation
selection factors include wind, seismic, support, use, and
access requirements in determination of appropriate systems.
Typically, the termination of real or personal property is
not one of the factors in the selection of foundation
systems.
Conclusion:
Any structure
can be relocated with enough time and money. The factors of
intrinsic design and the reality that every modular section
has already moved over public highways proves their
relocatability. Designs that are constructed on site, which
might be relocated, rarely take into consideration these
costly relocation factors:
The
tremendous structural stress of relocation and
transportation. This stresses multiples of typical
earthquake stress loads. Is the site constructed building
specifically designed for this stress and does it have the
means to be lifted and transported by truck?
The ability
to move over public highways without significant permit
costs and efforts.
The
destruction of the structural integrity of the building, the
high cost of material loss due to disassembly, and the high
costs of re-assembly.
Relocation of
site constructed structures regularly requires an entirely
new review process of structural and systems approval, since
the design of the structure did not initially consider, and
was not approved as, a relocatable structure. This
frequently adds significant additional agency review time,
engineering, material, and labor costs to the relocation
process.
CONSTRUCTION DEFINITIONS:
MODULAR:
A method of construction that utilizes pre-engineered,
factory-fabricated structures in three dimensional sections
that are transported to be tied together on a school site.
Typically,
modular construction mean that between 80 to 95% are
completed at the factory and then delivered to the site for
final affixation.
CONVENTIONAL: A construction method that utilizes
assembly of structures on-site, employing multi-layered
design and construction processes.
PERMANENT:
Commercial structures serving fixed or lasting facility
needs, and not envisioned to be removed or relocated. Can
utilize either conventional or modular construction methods.
RELOCATABLE: Commercial structures utilizing modular
construction methods that can be transported over public
roads. Designed to be constructed for efficient secondary
relocations without the removal of either the floor, roof,
or other significant structural modification. Frequently
called Portables, and generally under 2000 sq. feet in size.
|